top of page

Incinerator เตาเผาขยะ

เตาเผาขยะ,เตาเผาขยะปลอดเชื้อ,เต��าเผาขยะปลอดมลพิษ

Pollution-free infectious waste incinerator features
1. Quality of pollution-free infectious waste incinerator is in accordance with standard criteria of the Ministry of Natural Resources and Environment.
2. Built with quality materials - equipment making incinerator durable and last for long lifetime.
3. Prefabricated incinerator, it can be installed and used immediately and can be moved in order to change installation location. A whole incinerator system weighs up to five tons.
4. There are reports that measure pollution from pollution-free infectious waste incinerator chimney in the models offered by state agencies or private sector with registered analysis laboratory who has been registered to Department of Industrial Works. Air pollution monitoring is done at incinerator chimney using methods under US.EPA standard, calculated relative to dry weather condition, standard temperature and pressure and 7 percent oxygen. The monitoring results of air release from infectious waste incinerator of DAEHAETHAI are in accordance with Notification of Ministry of Science, Technology and Environment B.E. 2540 about standard control of polluted air emission from infectious incinerator. The measured values are as follows;
5. Auto and Manual control.
6. Able to use AC 220 V., do not have to apply for three-phase power systems.
7. The second combustion chamber is a vertical cylinder with smoke retardant system by air circulation at 45-degree angle helping to eliminate pollutants such as gas, smell smoke, dust, bacteria and other pollutants.
8. Able to perform automatic single combustion or continuous waste feeding into incinerator during combustion.
9. Able to burn both wet and dry waste without sorting prior to combustion.

 

Detail of Pollution-free infectious waste incinerator features
1. The incinerator has two combustion chambers. The first combustion chamber burns all solid waste and various materials, the second combustion chamber burns smell, gas, smoke, dust, bacteria and other pollutants.
2. External structure of first combustion chamber is made of 4 mm. thick durable steel.
3. Internal incinerator wall of first combustion chamber is lined with 200 mm. thick ceramic fiber and plastered over with fireproof concrete Cast 13 ES for 50 mm. of thickness, withstand heat up to 1,300 degree Celsius without refractory brick.
4. Internal incinerator floor is lined with 150 mm. thick ceramic fiber and plastered over with fireproof concrete Cast 13 ES for 100 mm. of thickness, withstand heat up to 1,300 degree Celsius.
5. External structure of second combustion chamber is made of 3 mm. thick durable steel.
6. Internal incinerator wall of second combustion chamber is lined with 200 mm. thick ceramic fiber and plastered over with fireproof concrete Cast 13 ES, withstand heat up to 1,300 degree Celsius without refractory brick.
7. External door structure is made of 4 mm. thick durable steel. Its interior is lined with 200 mm. thick ceramic fiber and plastered over with fireproof concrete Cast 13 ES, withstand heat up to 1,300 degree Celsius.
8. External structure of heat chimney is made of 2 mm. thick steel, not less than 5.00 m. tall. Its interior is lined with 125 mm. thick ceramic fiber and plastered over with fireproof concrete Cast 13 ES, withstand heat up to 1,300 degree Celsius with openable channel for air sampling.
9. Burner for first combustion chamber use AC 220 V 50/60 HZ electrical system, Light Fuel Oil or diesel fuel, fuel consumption rate at 10-30 kg/h, 400 W electric motor, 17 KV lighting transformer, controlled by Single Stage (ON-OFF), gear fuel pump. A quality product imported from foreign countries that meet ISO9001 standard and certified by the manufacturer of combustion head.
10. Burner for second combustion chamber use AC 220 V 50/60 HZ electrical system, Light Fuel Oil or diesel fuel, fuel consumption rate at 10-30 kg/h, 400 W electric motor, 17 KV lighting transformer, controlled by Two Stage (HIGH-LOW-OFF), gear fuel pump. A quality product imported from foreign countries that meet ISO9001 standard and certified by the manufacturer of combustion head.
11. Air compression fan in first combustion chamber and second combustion chamber use AC 2 Poles 50/60 HZ electrical system, 650 W electric motor, rotation rate 2950 rpm, blowing rate 25 m3/min, 0.75 horsepower. Air volume can be adjusted to different levels. The fan is powered by Single Phases electric motor 220 V.
12. Fuel storage system installed on incinerator has 150 liters capacity.
13. Control combustion with automatic. Display number with digital numeric value between 0 – 1,200 degree Celsius together with self-control adjustment with combustion head status light for both chambers. Easy to use.
14. Functional duration of second combustion chamber is not less than one second.
15. Use diesel or biodiesel fuel.
16. 1 set of ashtray and cleaning equipment provided inside incinerator.
17. Warranty and training for pollution-free infectious waste incinerator user And other relevant information include;
17.1 1 year warranty from delivery date or from the date of its last inspection. If pollution-free infectious waste incinerator or machine crash during normal use, pollution-free infectious waste incinerator shall be fixed without additional charge.
17.2 Monitor pollution-free infectious waste incinerator working condition every three months until the end of warranty.
17.3 Provide application and maintenance training for pollution-free infectious waste incinerator staffs, so that they can work properly. The training should at least include the following topics;
17.3.1 Training based on proper application of pollution-free infectious waste incinerator with regard to safety, saving, pollution elimination.
17.3.2 Training based on principles of pollution-free infectious waste incinerator and pollution-free infectious waste incinerator accessories.
17.3.3 Training and advice based on solid waste combustion for pollution-free infectious waste incinerator staffs, so that they can work properly.
17.4 2 sets of user and basic maintenance manual.